solinst model 403 cmt multilevel systems

Model 403 CMT Multilevel Systems

solinst 703 waterloo emitter uses oxygen to remediate btex in groundwater
solinst sonic water level meter

Proven & Effective for PFAS Monitoring

  • Provide the most accurate 3-D assessment of a PFAS site
  • Vital to understanding vertical PFAS contaminant transport
  • Allow documentation of changes in the concentration and delineation of PFAS contaminant plumes
  • Low cost compared to multiple individual wells
  • Minimize site disturbance
solinst 403 cmt multilevel systems ideal for pfas sites

Ideal for PFAS Sites

Over 10,000 Installations Worldwide

  • Single tube for effective sealing – no joints
  • Easy to install in one day
  • Typical backfill or sand/bentonite installation

Obtain detailed depth discrete groundwater data using a CMT Multilevel System. Monitor up to 7 zones in one well.

solinst model 403 cmt multilevel systems installation collage

Webinar Replay: HydroTerra and Haley and Aldrich

The Transect Approach to Characterizing and Monitoring Dissolved Contaminant Plumes

Research Article: The Effect of Heterogeneity on the Distribution and Treatment of PFAS in a Complex Geologic Environment

*Article Quote: “The characterization and monitoring of the site was completed with the aid of a series of multilevel wells and continuous cores. The groundwater was monitored using three CMT Multilevel Systems (Solinst, Canada) including one 3-channel system and two 7-channel systems (Figure 1)…To characterize the groundwater prior to and post-injection, groundwater samples were collected for analyses of various chemical parameters including PFAS, BTEX, major cations [calcium (Ca), magnesium (Mg]) potassium (K), sodium (Na), iron (Fe)], manganese [Mn], and anions [chloride (Cl), nitrate (NO3), and sulfate (SO4)] using low-flow sampling methods (Puls and Barcelona, 1996).”

* McGregor R and Benevenuto L (2021)
The Effect of Heterogeneity on the Distribution and Treatment of PFAS in a Complex Geologic Environment. Front. Environ. Chem. 2:729779. https://doi.org/10.3389/fenvc.2021.729779

Research Article: Six pilot-scale studies evaluating the in situ treatment of PFAS in groundwater – Rick McGregor

**Article Quote: “The concentrations of the six PFAS within the groundwater sampled from the monitoring well and CMT within the CAC PRZ were all below the detection limit during the five post injection sampling events including samples collected on Day 549 (Figure 9). These results indicate that the PFAS were being effectively adsorbed by the CAC. Sampling and analysis of the CMT multilevel monitoring well indicated that the six PFAS were below their detection limits throughout the vertical extent of the plume including within the coarse‐grained sand seam”. Rick McGregor

** McGregor R. Six pilot‐scale studies
evaluating the in situ treatment of PFAS compounds in groundwater.
Remediation. 30:39–50. https://doi.org/10.1002/rem.21653

 

CMT Multilevel System Case Studies and Articles

planting 51 trees speeds up toluene cleanup efforts

Planting 51 Trees Speeds Up Toluene Cleanup Efforts

Eliminate going to the field to download your Levelogger data. Quickly and easily add cellular telemetry to your Levelogger monitoring wells. The LevelSender 5 is designed to connect to Direct Read Cables and Leveloggers, upgrading your current installation by adding cellular telemetry at an affordable price. The LevelSender is compact in design, and is simple to setup and maintain. Leverage your current Levelogger 5 assets and increase your efficiency by adding a LevelSender.

high resolution groundwater data proves value of cmt systems in botlek area

High-Resolution Groundwater Data Proves Value of CMT Systems in Botlek Area

Spectrasens exclusive distributor of Solinst in the Netherlands, proposed Solinst CMT Multilevel Monitoring Systems to help gather high-resolution groundwater data in the Botlek region.

extensive groundwater monitoring program at refinery in australia

Extensive Groundwater Monitoring Program At Refinery in Australia

HydroTerra, exclusive distributor of Solinst products in Australia, was recently given the task of providing three CMT Multilevel Systems to an alumina refinery in Queensland, Australia. The groundwater monitoring program at the refinery includes monitoring one 7-channel and two 3-channel CMT Systems, and also biannually sampling 90 groundwater monitoring wells located in and around the…

can multilevel groundwater monitoring really be inexpensive and simple

Can Multilevel Groundwater Monitoring Really Be Inexpensive and Simple?

The answer is yes – especially if you use a Solinst CMT Multilevel Groundwater Monitoring System. CMT Systems are low cost, quickly installed, and are easily customized to suit your multilevel groundwater and soil gas monitoring needs. What is CMT? CMT stands for Continuous Multichannel Tubing. CMT is continuously extruded medium-density polyethylene (MDPE) tubing that…

19 cmt multilevel systems successfully installed in challenging geology

19 CMT Multilevel Systems Successfully Installed in Challenging Geology

A facility in Pontypool, Wales, UK was once the location of a plastic forming plant. Over time, chemicals produced through the plastic forming processes were lost into the groundwater beneath the facility, creating a large contaminant plume. Years later it was determined that the plume is migrating off site. In order to intercept…

cmt used to measure mass flux at a complex site

CMT Used To Measure Mass Flux At A Complex Site

In a town in the Piedmont physiographic province, in the mid Atlantic, a proposed water supply well was contaminated with methyl tert butyl ether (MTBE). The well is located down gradient of several gas service stations with multiple known sources of MTBE. As such, a remedial effort was required by Virginia Department of Environmental Quality…

Related Products

solinst model 703 waterloo emitter bioremediation device

Enhanced Bioremediation

The Waterloo Emitter™ is a simple, low cost device designed for the bioremediation of contaminated groundwater. It enables oxygen or other amendments to diffuse through silicone or LDPE tubing in a controlled, uniform manner. Ideal for aerobic bioremediation of MTBE and BTEX, with minimal maintenance required.

solinst 408m micro double valve pump

3/8" Diameter Flexible Pneumatic Pump

The Micro Double Valve Pump has a remarkably small and flexible design. At 3/8" (10 mm) diameter it is small enough to sample groundwater from channels of a CMT System.

solinst model 410 peristaltic pumps

Rugged Peristaltic Pump

Compact, lightweight, and water-resistant, the Solinst Peristaltic Pump is designed for field use. One easy-access control allows various speeds and reversible flow. Ideal for shallow water and vapor sampling.

solinst model 103 tag line  for accurate pump and bailer deployments and accurate measuring of backfill layers during well construction

Tag Line – Rugged, Simple, Convenient

The Tag Line uses a weight attached to laser marked cable, mounted on a sturdy reel. Convenient for measuring depths during monitoring well construction.

solinst 105 well casing and depth indicator

Well Casing & Depth Indicator

The Model 105 Well Casing & Depth Indicator detects metal well casing and measures total well depth using one probe. Ideal during well construction or decommissioning.

solinst model 880 well mount field table

Make Your Life Easier In The Field

Consider making your life easier in the field by ordering one of our convenient Field Tables. We have two models available, Well-mount and Stand-alone, to keep your equipment organized and provide a clean, sturdy surface to hold your field tools.