Solinst 2-wire signals are converted to SDI-12 signals by the Solinst SDI-12 Interface Cable. One end of this cable has three wires which connect to an SDI-12 datalogger. These wires are colour-coded according to Table 1-1. The other end of the cable terminates in a Direct Read connection. This connects to the top of a Direct Read Cable for connection to a Solinst Levelogger. The Solinst Levelogger has a self-contained battery and does not use +12V DC power. The SDI-12 Interface Cable circuitry requires the 12V connection. The current draw is nominally around 15 - 25 mA at 12V DC. Idle current draw is ~0.1 mA.
| Wire Colour | SDI-12 Function | Connection | 
|---|---|---|
| Red | 12 Volt Line | +12V DC at SDI-12 Datalogger | 
| Black | Ground Line | Ground at SDI-12 Datalogger | 
| White | Serial Data Line | SDI-12 Data at SDI-12 Datalogger | 
Table 1-1 SDI-12 Interface Cable Wire Definitions
The communication settings for the Solinst SDI-12 Interface Cable hardware comply with the SDI-12 standard at 1200 baud, 1 start bit, 7 data bits, 1 parity bit (even parity), and 1 stop bit.
| Technical Specifications | |
|---|---|
| Standard Compliance | SDI-12 Standard, Version 1.3, July 18, 2005 | 
| +12V Input | 9.6V-16.0V | 
| Average Current Draw While Taking Readings | 15-25 mA | 
| Idle Current Draw | ~0.1 mA | 
| Direct Read Cable – Max Length | 1500 ft | 
| SDI-12 Cable Length – Max Length | 200 ft | 
| Environmental | IP-65 | 
Table 1-2 SDI-12 Technical Specifications